Blog

12/08/2019

Windows: Plesk Login Error: Unable to connect to pipe



This article describes how to fix a Plesk on Windows login error displaying the symptoms below.

Problem Description

You cannot connect to my Plesk Control Panel and receive the following error:

get_config_string failed: PRODUCT_DATA_D: The system cannot find the file specified.
(Error code 2) at Unable to connect to pipe \.pipepsapipe

Problem Cause

The Plesk services have lost their connection to the Plesk database.  There are several reasons this might happen, but the quick fix is the same in all cases.

Solution

The quick fix for this problem is to restart the Plesk services and the Plesk database servers.

Follow these steps to perform this action:

  1. Login to your server with Remote Desktop.
  2. Open the Plesk icon in your system tray.
  3. Select the Plesk Run-Time checkboxes so they are checked.
  4. Select the SQL Server boxes so they are checked.
  5. Uncheck everything else.
  6. Click the Restart button.

This will restart the services involved in the Plesk database connection and allow them to communicate.

===

Liquid Web’s Heroic Support is always available to assist customers with this or any other issue. If you need our assistance please contact us:
Toll Free 1.800.580.4985
International 517.322.0434
support@sxi.io
https://manage.sxi.io/

14/08/2019

How to KVM, QEMU start or stop virtual machine from command line (CLI)

KVM or Kernel Based Virtual Machine is a popular virtualization technology. It allows you to run virtual guest machines over a host machine. To start...
14/08/2019

How to Docker backup Saving and restoring your volumes

Running a Docker volume backup First, we spin up a temporary container, and we mount the backup folder and the target Docker volume to this container....
12/08/2019

How to Start and Enable Firewalld on CentOS 7

In this article, we discuss how to start and enable firewalld. It is highly recommended that you have a firewall protecting your server.Pre-Flight CheckThese...